Influence of site on thermal design of a two floor ZEH in the desert

Type
Conference Paper

Authors
Serag-Eldin, M. A.

Date
2010-12

Abstract
The paper presents the results of investigating the effect of Latitude angle and environmental temperature on the thermal behavior and performance of a fully equipped, air-conditioned, zero energy house located in a desert residential compound. It makes use of the thermal design and analysis tools presented in other work and extends the investigation to include different site environmental characteristics. Data from eight different meteorological sites in the KSA where considered. It is demonstrated that for the same house and occupancy profile, the PV modules, battery storage, and air-conditioning equipment requirements can differ markedly depending on local environment properties. During Summer and Spring the main heat load is due to cooling, but during winter season the load can vary from full cooling, to mixed cooling and heating, to even full heating; the heating load sometimes dictating the size of the required equipment. © 2010 IEEE.

Citation
Serag-Eldin MA (2010) Influence of site on thermal design of a two floor ZEH in the desert. 2010 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications. Available: http://dx.doi.org/10.1109/THETA.2010.5766406.

Acknowledgements
This work was funded by the King Abdalla Universityfor Science and Technology (KAUST) project onIntegrated Desert Building Technologies, the grant heldby AUC.

Publisher
Institute of Electrical and Electronics Engineers (IEEE)

Journal
2010 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications

DOI
10.1109/THETA.2010.5766406

Permanent link to this record