A widely tunable difference-frequency-generation laser for high-resolution spectroscopy in the 667-865 cm-1range
dc.contributor.author | Shakfa, Mohammad Khaled | |
dc.contributor.author | Lamperti, Marco | |
dc.contributor.author | Gotti, Riccardo | |
dc.contributor.author | Gatti, Davide | |
dc.contributor.author | Elkhazraji, Ali | |
dc.contributor.author | Hakimov, Khaiyom | |
dc.contributor.author | Marangoni, Marco | |
dc.contributor.author | Farooq, Aamir | |
dc.date.accessioned | 2021-06-09T06:42:33Z | |
dc.date.available | 2021-06-09T06:42:33Z | |
dc.date.issued | 2021-03-05 | |
dc.identifier.citation | Shakfa, M. K., Lamperti, M., Gotti, R., Gatti, D., Elkhazraji, A., Hakimov, K., … Farooq, A. (2021). A widely tunable difference-frequency-generation laser for high-resolution spectroscopy in the 667–865 cm–1 range. Nonlinear Frequency Generation and Conversion: Materials and Devices XX. doi:10.1117/12.2577534 | |
dc.identifier.isbn | 9781510641754 | |
dc.identifier.issn | 1996-756X | |
dc.identifier.issn | 0277-786X | |
dc.identifier.doi | 10.1117/12.2577534 | |
dc.identifier.uri | http://hdl.handle.net/10754/669473 | |
dc.description.abstract | Mid-infrared (MIR) laser sources are used in a number of applications such as remote sensing, air pollution monitoring, combustion diagnostics, and molecular spectroscopy. Here, we present our work on the development of a MIR laser source based on the difference frequency generation (DFG) process between an external-cavity quantum-cascade-laser tunable over 1750-1835 cm-1 (pump source) and a CO2 gas laser tunable over 921-1083 cm-1 (signal source). The DFG process was realized in a nonlinear, orientation-patterned GaAs crystal, and resulted in an idler spectral range between 667-865 cm-1 with a linewidth of ∼2.3 MHz and an output power of up to ∼31 μW. Exploiting the fine tunability of our DFG laser source, we performed high-resolution absorption measurements of ethylene (C2H4) and acetylene (C2H2). | |
dc.description.sponsorship | This work was funded by the Office of Sponsored Research (OSR) at King Abdullah University of Science and Technology (KAUST). | |
dc.publisher | SPIE | |
dc.relation.url | https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11670/2577534/A-widely-tunable-difference-frequency-generation-laser-for-high-resolution/10.1117/12.2577534.full | |
dc.rights | Archived with thanks to SPIE | |
dc.title | A widely tunable difference-frequency-generation laser for high-resolution spectroscopy in the 667-865 cm-1range | |
dc.type | Conference Paper | |
dc.contributor.department | Chemical Kinetics & Laser Sensors Laboratory | |
dc.contributor.department | Clean Combustion Research Center | |
dc.contributor.department | Mechanical Engineering | |
dc.contributor.department | Mechanical Engineering Program | |
dc.contributor.department | Physical Science and Engineering (PSE) Division | |
dc.conference.date | 2021-03-06 to 2021-03-11 | |
dc.conference.name | Nonlinear Frequency Generation and Conversion: Materials and Devices XX 2021 | |
dc.conference.location | Virtual, Online, USA | |
dc.eprint.version | Post-print | |
dc.contributor.institution | Politecnico di Milano, Department of Physics and IFN-CNR, Via G. Previati 1/C, 23900 Lecco, Italy | |
dc.identifier.volume | 11670 | |
kaust.person | Shakfa, Mohammad Khaled | |
kaust.person | Elkhazraji, Ali | |
kaust.person | Hakimov, Khaiyom | |
kaust.person | Farooq, Aamir | |
dc.identifier.eid | 2-s2.0-85107050080 | |
refterms.dateFOA | 2021-06-13T10:22:08Z | |
kaust.acknowledged.supportUnit | Office of Sponsored Research (OSR) |
Files in this item
This item appears in the following Collection(s)
-
Conference Papers
-
Physical Science and Engineering (PSE) Division
For more information visit: http://pse.kaust.edu.sa/ -
Mechanical Engineering Program
For more information visit: https://pse.kaust.edu.sa/study/academic-programs/mechanical-engineering/Pages/home.aspx -
Clean Combustion Research Center