dc.identifier.citationJamil, M. A., Xu, B. B., Dala, L., Sultan, M., Jie, L., & Shahzad, M. W. (2021). Experimental and normalized sensitivity based numerical analyses of a novel humidifier-assisted highly efficient indirect evaporative cooler. International Communications in Heat and Mass Transfer, 125, 105327. doi:10.1016/j.icheatmasstransfer.2021.105327
dc.identifier.issn0735-1933
dc.identifier.doi10.1016/j.icheatmasstransfer.2021.105327
dc.identifier.urihttp://hdl.handle.net/10754/669313
dc.description.abstractIndirect evaporative cooling technology has emerged as an energy-efficient, low-cost, and sustainable alternative to conventional air conditioning systems for space cooling. This is because of its significant (40–50%) energy-saving potential compared to ventilation, vapor compression cooling, and desiccant cooling systems. The current paper presents a novel humidifier-assisted regenerative indirect evaporative cooler that eliminates the use of hydrophilic surfaces within the system and mitigates the fouling propensity and water management issues. A generic cell of the proposed system is fabricated and tested for different operating scenarios along with the uncertainty propagation analysis. Thereafter, a normalized sensitivity analysis is performed to identify the most influential parameters on the cooler performance. The experimental data shows an effective cooling performance with a temperature drop of 20 °C of outdoor air and cooling capacity of 175 watts of 1800 mm × 300 mm generic cell. The cooling coefficient of performance was calculated as 44 and maximum effectiveness of 83.82% for the proposed configuration. The sensitivity analysis reveals scaling trends of the coefficient of performance in the following order of primary air inlet temperature > primary air outlet temperature > primary air velocity and the cooler effectiveness as secondary air outlet temperature > primary air inlet temperature > primary air humidity > primary air outlet.
dc.description.sponsorshipThe authors would like to thank KCI project by OSR KAUST Saudi Arabia and support provided by Northumbria University, UK under reference # RDF20/EE/MCE/SHAHZAD and MCE QR Steering Fund 2020/21.
dc.publisherElsevier BV
dc.relation.urlhttps://linkinghub.elsevier.com/retrieve/pii/S0735193321002207
dc.rights©2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleExperimental and normalized sensitivity based numerical analyses of a novel humidifier-assisted highly efficient indirect evaporative cooler
dc.typeArticle
dc.contributor.departmentBiological and Environmental Science and Engineering (BESE) Division
dc.contributor.departmentWater Desalination and Reuse Research Center (WDRC)
dc.identifier.journalInternational Communications in Heat and Mass Transfer
dc.eprint.versionPublisher's Version/PDF
dc.contributor.institutionMechanical & Construction Engineering Department, Northumbria University, Newcastle Upon Tyne NE1 8ST, United Kingdom
dc.contributor.institutionDepartment of Agricultural Engineering, Bahauddin Zakariya University, Bosan Road, Multan 60800, Pakistan
dc.contributor.institutionDepartment of Engineering Science, University of Oxford, Oxford OX1 3PJ, United Kingdom
dc.identifier.volume125
dc.identifier.pages105327
kaust.personShahzad, Muhammad Wakil
refterms.dateFOA2021-05-31T08:07:00Z
kaust.acknowledged.supportUnitOSR
dc.date.published-online2021-05-18
dc.date.published-print2021-06


Files in this item

Thumbnail
Name:
1-s2.0-S0735193321002207-main.pdf
Size:
7.919Mb
Format:
PDF
Description:
Published Version

This item appears in the following Collection(s)

Show simple item record

©2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
Except where otherwise noted, this item's license is described as ©2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.