• Login
    View Item 
    •   Home
    • Research
    • Articles
    • View Item
    •   Home
    • Research
    • Articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of KAUSTCommunitiesIssue DateSubmit DateThis CollectionIssue DateSubmit Date

    My Account

    Login

    Quick Links

    Open Access PolicyORCID LibguideTheses and Dissertations LibguideSubmit an Item

    Statistics

    Display statistics

    Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    postprint (3).pdf
    Size:
    985.4Kb
    Format:
    PDF
    Description:
    Accepted Manuscript
    Download
    Thumbnail
    Name:
    mrm28066-sup-0001-supinfo.pdf
    Size:
    1.296Mb
    Format:
    PDF
    Description:
    Supplementary material
    Download
    Type
    Article
    Authors
    Dehghani, Masoumeh
    Do, Kim Q.
    Magistretti, Pierre J. cc
    Xin, Lijing cc
    KAUST Department
    Biological and Environmental Sciences and Engineering (BESE) Division
    Bioscience Program
    Date
    2019-01-01
    Online Publication Date
    2019-11-14
    Print Publication Date
    2020-06
    Embargo End Date
    2020-01-01
    Permanent link to this record
    http://hdl.handle.net/10754/660452
    
    Metadata
    Show full item record
    Abstract
    Purpose: This assesses the potential of measuring lactate in the human brain using three non-editing MRS methods at 7T and compares the accuracy and precision of the methods. Methods: 1H MRS data were measured in the right dorsolateral prefrontal cortex using a semi-adiabatic spin-echo full-intensity acquired localized sequence with three different protocols: (I) TE = 16 ms, (II) TE = 110 ms, and (III) TE = 16 ms, TI = 300 ms. T1 and T2 relaxation times of lactate were also measured. Simulated spectra were generated for three protocols with known concentrations, using a range of spectral linewidths and SNRs to assess the effect of data quality on the measurement precision and accuracy. Results: Lactate was quantified in all three protocols with mean Cramér-Rao lower bound of 8% (I), 13% (II), and 7% (III). The T1 and T2 relaxation times of lactate were 1.9 ± 0.2 s and 94 ± 13 ms, respectively. Simulations predicted a spectral linewidth-associated underestimation of lactate measurement. Simulations, phantom and in vivo results showed that protocol II was most affected by this underestimation. In addition, the estimation error was insensitive to a broad range of spectral linewidth with protocol I. Within-session coefficient of variances of lactate were 6.1 ± 7.9% (I), 22.3 ± 12.3% (II), and 5.1 ± 5.4% (III), respectively. Conclusion: We conclude that protocols I and III have the potential to measure lactate at 7T with good reproducibility, whereas the measurement accuracy and precision depend on spectral linewidth and SNR, respectively. Moreover, simulation is valuable for the optimization of measurement protocols in future study design and the correction for measurement bias.
    Citation
    Dehghani, M., Do, K. Q., Magistretti, P., & Xin, L. (2019). Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times. Magnetic Resonance in Medicine. doi:10.1002/mrm.28066
    Sponsors
    We are grateful to Dr. Hikari Yoshihara for proofread-ing this manuscript and Prof. Rolf Gruetter for his kind support. This study was supported by Centre d’Imagerie BioMédicale (CIBM) of the UNIL, UNIGE, HUG, CHUV, EPFL, the Leenaards and Jeantet Foundations, the National Center of Competence in Research (NCCR) “SYNAPSY-The Synaptic Bases of Mental Diseases” financed by the Swiss National Science Foundation (51AU40_125759) and the Biaggi Foundation.
    Publisher
    Wiley
    Journal
    Magnetic Resonance in Medicine
    DOI
    10.1002/mrm.28066
    Additional Links
    https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.28066
    https://infoscience.epfl.ch/record/272764/files/postprint.pdf
    ae974a485f413a2113503eed53cd6c53
    10.1002/mrm.28066
    Scopus Count
    Collections
    Articles; Biological and Environmental Science and Engineering (BESE) Division; Bioscience Program

    entitlement

     
    DSpace software copyright © 2002-2023  DuraSpace
    Quick Guide | Contact Us | KAUST University Library
    Open Repository is a service hosted by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items. For anonymous users the allowed maximum amount is 50 search results.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.