A bilayered PVA/PLGA-bioresorbable shuttle to improve the implantation of flexible neural probes
Type
ArticleAuthors
Pas, Jolien
Rutz, Alexandra L.
Quilichini, Pascale

Slézia, Andrea
Ghestem, Antoine
Kaszas, Attila
Donahue, Mary
Curto, Vincenzo
O’Connor, Rodney P.
bernard, christophe

Williamson, Adam
Malliaras, George
KAUST Grant Number
OSR-2016-CRG5-3003Date
2018-09-11Online Publication Date
2018-09-11Print Publication Date
2018-12-01Permanent link to this record
http://hdl.handle.net/10754/629801
Metadata
Show full item recordAbstract
Objective: Neural electrophysiology is often conducted with traditional, rigid depth probes. The mechanical mismatch between these probes and soft brain tissue is unfavorable for tissue interfacing. Making probes compliant can improve biocompatibility, but as a consequence, they become more difficult to insert into the brain. Therefore, new methods for inserting compliant neural probes must be developed. \n Approach: Here, we present a new bioresorbable shuttle based on the hydrolytically degradable poly(vinyl alcohol) (PVA) and poly(lactic-co-glycolic acid) (PLGA). We show how to fabricate the PVA/PLGA shuttles on flexible and thin parylene probes. The method consists of PDMS molding used to fabricate a PVA shuttle aligned with the probe and to also impart a sharp tip necessary for piercing brain tissue. The PVA shuttle is then dip-coated with PLGA to create a bi-layered shuttle. \n Main results: While single layered PVA shuttles are able to penetrate agarose brain models, only limited depths were achieved and repositioning was not possible due to the fast degradation. We demonstrate that a bilayered approach incorporating a slower dissolving PLGA layer prolongs degradation and enables facile insertion for at least several millimeters depth. Impedances of electrodes before and after shuttle preparation were characterized and showed that careful deposition of PLGA is required to maintain low impedance. Facilitated by the shuttles, compliant parylene probes were also successfully implanted into anaesthetized mice and enabled the recording of high quality local field potentials. \n Significance: This work thereby presents a solution towards addressing a key challenge of implanting compliant neural probes using a two polymer system. PVA and PLGA are polymers with properties ideal for translation: commercially available, biocompatible with FDA-approved uses and bioresorbable. By presenting new ways to implant compliant neural probes, we can begin to fully evaluate their chronic biocompatibility and performance compared to traditional, rigid electronics.Citation
Pas J, Rutz AL, Quilichini PP, Slézia A, Ghestem A, et al. (2018) A bilayered PVA/PLGA-bioresorbable shuttle to improve the implantation of flexible neural probes. Journal of Neural Engineering 15: 065001. Available: http://dx.doi.org/10.1088/1741-2552/aadc1d.Sponsors
The authors acknowledge support from the “Fondation pour la Recherche Médicale” under grant agreement DBS20131128446, the Whitaker International Program (A.R.), the European Union's Horizon 2020 Research and Innovation Programme under grant agreement No. 732032 (BrainCom), and the King Abdullah University of Science and Technology (KAUST) Office of Sponsored Research (OSR) under award No. OSR-2016-CRG5-3003. In addition, A.S., A.K. and A.W. acknowledge support from the European Research Council (ERC) under the European Union’s Horizon 2020 research and Innovation Program (grant agreement No 716867). A.K. was financed by EC Marie Curie Intra-European Fellowship (ImagINE, grant agreement No 625372).Publisher
IOP PublishingJournal
Journal of Neural Engineeringae974a485f413a2113503eed53cd6c53
10.1088/1741-2552/aadc1d