Localized Electrochemiluminescence from Nanoneedle Electrodes for Very-high-density Electrochemical Sensing
dc.contributor.author | Zhang, Jingjing | |
dc.contributor.author | Zhou, Junyu | |
dc.contributor.author | Tian, Chunxiu | |
dc.contributor.author | Yang, Shan | |
dc.contributor.author | Jiang, Dechen | |
dc.contributor.author | Zhang, Xixiang | |
dc.contributor.author | Chen, Hong-Yuan | |
dc.date.accessioned | 2017-10-30T08:39:51Z | |
dc.date.available | 2017-10-30T08:39:51Z | |
dc.date.issued | 2017-10-10 | |
dc.identifier.citation | Zhang J, Zhou J, Tian C, Yang S, Jiang D, et al. (2017) Localized Electrochemiluminescence from Nanoneedle Electrodes for Very-High-Density Electrochemical Sensing. Analytical Chemistry. Available: http://dx.doi.org/10.1021/acs.analchem.7b02363. | |
dc.identifier.issn | 0003-2700 | |
dc.identifier.issn | 1520-6882 | |
dc.identifier.pmid | 28956903 | |
dc.identifier.doi | 10.1021/acs.analchem.7b02363 | |
dc.identifier.uri | http://hdl.handle.net/10754/626021 | |
dc.description.abstract | In this paper, localized electrochemiluminescence (ECL) was visualized from nanoneedle electrodes that achieved very-high-density electrochemical sensing. The localized luminescence at the nanometer-sized tip observed was ascribed to enhanced mass transfer of the luminescence probe at the tip than on the planar surface surrounding the tip, which provided higher luminescence at the tip. The size of the luminescence spots was restricted to 15 μm permitting the electrochemical analysis with a density over 4 × 103 spots/mm2. The positive correlation between the luminescence intensity at the tips and the concentration of hydrogen peroxide supported the quantitative ECL analysis using nanoneedle electrodes. The further modification of glucose oxidase at the electrode surface conceptually demonstrated that the concentration of glucose ranging from 0.5 to 5 mM could be quantified using the luminescence at the tips, which could be further applied for the detection of multiple molecules in the complex biosystem. This successful localized ECL offers a specific strategy for the development of very-high-density electrochemical arrays without the complicated chip design. | |
dc.description.sponsorship | This work was supported by National Key Research and Development Program (Grant 2016YFA0201203) and the National Natural Science Foundation of China (Grants 21327902 and 21575060). C.T., S.Y., and X.-X.Z. would like to acknowledge the financial support from King Abdullah University of Science and Technology (KAUST). | |
dc.publisher | American Chemical Society (ACS) | |
dc.relation.url | http://pubs.acs.org/doi/abs/10.1021/acs.analchem.7b02363 | |
dc.title | Localized Electrochemiluminescence from Nanoneedle Electrodes for Very-high-density Electrochemical Sensing | |
dc.type | Article | |
dc.contributor.department | Biological and Environmental Sciences and Engineering (BESE) Division | |
dc.contributor.department | Material Science and Engineering Program | |
dc.contributor.department | Physical Science and Engineering (PSE) Division | |
dc.identifier.journal | Analytical Chemistry | |
dc.contributor.institution | State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering Nanjing University, Nanjing, Jiangsu 210093, China | |
kaust.person | Tian, Chunxiu | |
kaust.person | Yang, Shan | |
kaust.person | Zhang, Xixiang | |
dc.date.published-online | 2017-10-10 | |
dc.date.published-print | 2017-11-07 |
This item appears in the following Collection(s)
-
Articles
-
Biological and Environmental Science and Engineering (BESE) Division
For more information visit: https://bese.kaust.edu.sa/ -
Physical Science and Engineering (PSE) Division
For more information visit: http://pse.kaust.edu.sa/ -
Material Science and Engineering Program
For more information visit: https://pse.kaust.edu.sa/study/academic-programs/material-science-and-engineering/Pages/default.aspx