dc.description.abstractElectrical tomography can be used as a structural health monitoring technique to identify different damage mechanisms in composite laminates. Previous work has established the link between transverse cracking density and mesoscale conductivity of the ply. Through the mesoscale relationship, the conductivity obtained from electrical tomography can be used as a measure of the transverse cracking density. Interpretation of this measure will be accurate provided the assumptions made during homogenization are valid. One main assumption of mesoscale homogenization is that the electric field is in the plane. Here, we test the validity of this assumption for laminates with varying anisotropy ratios and for different distances between the cracked ply and surface that is instrumented with electrodes. We also show the equivalence in electrical response between measurements from cracked laminates and their equivalent mesoscale counterparts. Finally, we propose some general guidelines on the measurement strategy for maximizing the accuracy of transverse cracks identification.
dc.description.sponsorshipThe research reported in this publication was supported by funding from King Abdullah University of Science and Technology (KAUST).
dc.language.isoen
dc.publisherMDPI AG
dc.relation.urlhttp://www.mdpi.com/1424-8220/16/4/427
dc.rightsThis is an open access article distributed under the Creative Commons Attribution License (CC BY) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0/
dc.subjecttransverse cracking
dc.subjectelectrical tomography
dc.subjectsensitivity
dc.subjectlaminated composites
dc.titleEffect of Voltage Measurement on the Quantitative Identification of Transverse Cracks by Electrical Measurements
dc.typeArticle
dc.contributor.departmentComposite and Heterogeneous Material Analysis and Simulation Laboratory (COHMAS)
dc.contributor.departmentMechanical Engineering Program
dc.contributor.departmentPhysical Science and Engineering (PSE) Division
dc.identifier.journalSensors
dc.eprint.versionPublisher's Version/PDF
dc.contributor.affiliationKing Abdullah University of Science and Technology (KAUST)
kaust.personSelvakumaran, Lakshmi
refterms.dateFOA2018-06-13T10:20:40Z


Files in this item

Thumbnail
Name:
sensors-16-00427-v2.pdf
Size:
2.596Mb
Format:
PDF
Description:
Main article

This item appears in the following Collection(s)

Show simple item record