Show simple item record

dc.contributor.authorSmith, Amy F.
dc.contributor.authorShipley, Rebecca J.
dc.contributor.authorLee, Jack
dc.contributor.authorSands, Gregory B.
dc.contributor.authorLeGrice, Ian J.
dc.contributor.authorSmith, Nicolas P.
dc.date.accessioned2016-02-28T06:35:25Z
dc.date.available2016-02-28T06:35:25Z
dc.date.issued2014-05-28
dc.identifier.citationSmith AF, Shipley RJ, Lee J, Sands GB, LeGrice IJ, et al. (2014) Transmural Variation and Anisotropy of Microvascular Flow Conductivity in the Rat Myocardium. Ann Biomed Eng 42: 1966–1977. Available: http://dx.doi.org/10.1007/s10439-014-1028-2.
dc.identifier.issn0090-6964
dc.identifier.issn1573-9686
dc.identifier.pmid24866569
dc.identifier.doi10.1007/s10439-014-1028-2
dc.identifier.urihttp://hdl.handle.net/10754/600069
dc.description.abstractTransmural variations in the relationship between structural and fluid transport properties of myocardial capillary networks are determined via continuum modeling approaches using recent three-dimensional (3D) data on the microvascular structure. Specifically, the permeability tensor, which quantifies the inverse of the blood flow resistivity of the capillary network, is computed by volume-averaging flow solutions in synthetic networks with geometrical and topological properties derived from an anatomically-detailed microvascular data set extracted from the rat myocardium. Results show that the permeability is approximately ten times higher in the principal direction of capillary alignment (the "longitudinal" direction) than perpendicular to this direction, reflecting the strong anisotropy of the microvascular network. Additionally, a 30% increase in capillary diameter from subepicardium to subendocardium is shown to translate to a 130% transmural rise in permeability in the longitudinal capillary direction. This result supports the hypothesis that perfusion is preferentially facilitated during diastole in the subendocardial microvasculature to compensate for the severely-reduced systolic perfusion in the subendocardium.
dc.description.sponsorshipThe authors acknowledge support from the Virtual Physiological Rat Project (NIH1 P50 GM094503-1), the EPSRC (Engineering and Physical Sciences Research Council) under grant numbers EP/F043929/1 and EP/G007527/2, and Award No. KUK-C1-013-04 made by King Abdullah University of Science and Technology (KAUST). The authors would also like to thank Prof. Timothy W. Secomb (University of Arizona) for helpful scientific discussions.
dc.publisherSpringer Nature
dc.subjectDarcy flow
dc.subjectFlow conductivity
dc.subjectHomogenization
dc.subjectMicrovascular networks
dc.subjectMyocardial blood flow
dc.subjectTransmural functional differences
dc.subject.meshMicrocirculation
dc.subject.meshCoronary Circulation
dc.titleTransmural Variation and Anisotropy of Microvascular Flow Conductivity in the Rat Myocardium
dc.typeArticle
dc.identifier.journalAnnals of Biomedical Engineering
dc.identifier.pmcidPMC4404518
dc.contributor.institutionOxford Centre for Collaborative Applied Mathematics, Mathematical Institute, University of Oxford, Woodstock Road, Oxford, OX2 6GG, UK.
kaust.grant.numberKUK-C1-013-04
dc.date.published-online2014-05-28
dc.date.published-print2014-09


This item appears in the following Collection(s)

Show simple item record