Show simple item record

dc.contributor.authorDavis, Robert J.
dc.contributor.authorKim, Younggy
dc.contributor.authorLogan, Bruce E.
dc.date.accessioned2016-02-25T13:33:05Z
dc.date.available2016-02-25T13:33:05Z
dc.date.issued2013-09-03
dc.identifier.citationDavis RJ, Kim Y, Logan BE (2013) Increasing Desalination by Mitigating Anolyte pH Imbalance Using Catholyte Effluent Addition in a Multi-Anode Bench Scale Microbial Desalination Cell. ACS Sustainable Chem Eng 1: 1200–1206. Available: http://dx.doi.org/10.1021/sc400148j.
dc.identifier.issn2168-0485
dc.identifier.issn2168-0485
dc.identifier.doi10.1021/sc400148j
dc.identifier.urihttp://hdl.handle.net/10754/598611
dc.description.abstractA microbial desalination cell (MDC) uses exoelectrogenic bacteria to oxidize organic matter while desalinating water. Protons produced from the oxidation of organics at the anode result in anolyte acidification and reduce performance. A new method was used here to mitigate anolyte acidification based on adding non-buffered saline catholyte effluent from a previous cycle to the anolyte at the beginning of the next cycle. This method was tested using a larger-scale MDC (267 mL) containing four anode brushes and a three cell pair membrane stack. With an anolyte salt concentration increased by an equivalent of 75 mM NaCl using the catholyte effluent, salinity was reduced by 26.0 ± 0.5% (35 g/L NaCl initial solution) in a 10 h cycle, compared to 18.1 ± 2.0% without catholyte addition. This improvement was primarily due to the increase in buffering capacity of the anolyte, although increased conductivity slightly improved performance as well. There was some substrate loss from the anolyte by diffusion into the membrane stack, but this was decreased from 11% to 2.6% by increasing the anolyte conductivity (7.6 to 14 mS/cm). These results demonstrated that catholyte effluent can be utilized as a useful product for mitigating anolyte acidification and improving MDC performance. © 2013 American Chemical Society.
dc.description.sponsorshipThe authors thank Siemens Corp. for kindly donating an electrodialysis reactor as a design reference for this project, Hiroyuki Kashima for his help with ion chromatography, and Dr. Xiuping Zhu for conducting the HPLC analysis. This research was supported by Award KUS-11-003-13 from the King Abdullah University of Science and Technology (KAUST).
dc.publisherAmerican Chemical Society (ACS)
dc.subjectAnolyte acidification
dc.subjectDesalination
dc.subjectElectrolyte recycle
dc.subjectMDC
dc.subjectMicrobial desalination cell
dc.subjectMulti-anode
dc.titleIncreasing Desalination by Mitigating Anolyte pH Imbalance Using Catholyte Effluent Addition in a Multi-Anode Bench Scale Microbial Desalination Cell
dc.typeArticle
dc.identifier.journalACS Sustainable Chemistry & Engineering
dc.contributor.institutionPennsylvania State University, State College, United States
dc.contributor.institutionMcMaster University, Hamilton, Canada
kaust.grant.numberKUS-11-003-13