Multicomponent mixed dopant optimization for rapid screening of polycyclic aromatic hydrocarbons using ultra high performance liquid chromatography coupled to atmospheric pressure photoionization high-resolution mass spectrometry
Type
ArticleKAUST Department
Analytical Chemistry Core LabAnalytical Core Lab
Core Labs
Date
2012-05-04Online Publication Date
2012-05-04Print Publication Date
2012-06-30Permanent link to this record
http://hdl.handle.net/10754/562179
Metadata
Show full item recordAbstract
RATIONALE To enhance the ionization efficiencies in atmospheric pressure photoionization mass spectrometry a dopant with favorable ionization energy such as chlorobenzene is typically used. These dopants are typically toxic and difficult to mix with water-soluble organic solvents. In order to achieve a more efficient and less toxic dopant, a multicomponent mixed dopant was explored. METHODS A multicomponent mixed dopant for non-targeted rapid screening of polycyclic aromatic hydrocarbons (PAHs) was developed and optimized using ultra high performance liquid chromatography (UPLC) coupled to atmospheric pressure photoionization high-resolution mass spectrometry. Various single and multicomponent mixed dopants consisting of ethanol, chlorobenzene, bromobenzene, anisole and toluene were evaluated. RESULTS Fourteen out of eighteen PAHs were successfully separated and detected at low pg/μL levels within 5 min with high mass accuracy ≤4 ppm. The optimal mixed multicomponent dopant consisted of ethanol/chlorobenzene/bromobenzene/anisole (98.975:0.1:0.9:0.025, v/v %) and it improved the limit of detection (LOD) by 2- to 10-fold for the tested PAHs compared to those obtained with pure chlorobenzene. CONCLUSIONS A novel multicomponent dopant that contains 99% ethanol and 1% mixture of chlorobenzene, bromobenzene and anisole was found to be an effective dopant mixture to ionize PAHs. The developed UPLC multicomponent dopant assisted atmospheric pressure photoionization high-resolution mass spectrometry offered a rapid non targeted screening method for detecting the PAHs at low pg/;μL levels within a 5 min run time with high mass accuracy a;circ4 ppm. Copyright © 2012 John Wiley & Sons, Ltd.Citation
Amad, S. S. M., & Al-Talla, Z. A. (2012). Multicomponent mixed dopant optimization for rapid screening of polycyclic aromatic hydrocarbons using ultra high performance liquid chromatography coupled to atmospheric pressure photoionization high-resolution mass spectrometry. Rapid Communications in Mass Spectrometry, 26(12), 1488–1496. doi:10.1002/rcm.6250Sponsors
The authors gratefully acknowledge the research support from the Analytical Core Lab at the King Abdullah University of Science and Technology, Saudi Arabia.Publisher
WileyDOI
10.1002/rcm.6250PubMed ID
22592993ae974a485f413a2113503eed53cd6c53
10.1002/rcm.6250
Scopus Count
Related articles
- Optimization of the dopant for the trace determination of polycyclic aromatic hydrocarbons by liquid chromatography/dopant-assisted atmospheric-pressure photoionization/mass spectrometry.
- Authors: Itoh N, Aoyagi Y, Yarita T
- Issue date: 2006 Oct 27
- Ultra performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry for high-sensitivity and high-throughput analysis of U.S. Environmental Protection Agency 16 priority pollutants polynuclear aromatic hydrocarbons.
- Authors: Cai SS, Syage JA, Hanold KA, Balogh MP
- Issue date: 2009 Mar 15
- Ionization of EPA contaminants in direct and dopant-assisted atmospheric pressure photoionization and atmospheric pressure laser ionization.
- Authors: Kauppila TJ, Kersten H, Benter T
- Issue date: 2015 Jun
- Design and evaluation of a dopant-delivery system for an orthogonal atmospheric-pressure photoionization source and its performance in the analysis of polycyclic aromatic hydrocarbons.
- Authors: Ehrenhauser FS, Wornat MJ, Valsaraj KT, Rodriguez P
- Issue date: 2010 May 15