Elemental Quantification and Residues Characterization of Wet Digested Certified and Commercial Carbon Materials

Handle URI:
http://hdl.handle.net/10754/622753
Title:
Elemental Quantification and Residues Characterization of Wet Digested Certified and Commercial Carbon Materials
Authors:
Simoes, Filipa R. F.; Batra, Nitin M.; Warsama, Bashir H.; Canlas, Christian; Patole, Shashikant; Yapici, Tahir F.; Costa, Pedro M. F. J.
Abstract:
Inductively coupled plasma optical emission spectroscopy (ICP-OES) is a common, relatively low cost, and straightforward analytical technique for the study of trace quantities of metals in solid materials, but its applicability to nanocarbons (e.g., graphene and nanotubes) has suffered from the lack of efficient digestion steps and certified reference materials (CRM). Here, various commercial and certified graphitic carbon materials were subjected to a
KAUST Department:
Imaging and Characterization Core Lab
Citation:
Simoes FRF, Batra NM, Warsama BH, Canlas CG, Patole S, et al. (2016) Elemental Quantification and Residues Characterization of Wet Digested Certified and Commercial Carbon Materials. Analytical Chemistry 88: 11783–11790. Available: http://dx.doi.org/10.1021/acs.analchem.6b03407.
Publisher:
American Chemical Society (ACS)
Journal:
Analytical Chemistry
KAUST Grant Number:
BAS/1/1346-01-01
Issue Date:
25-Oct-2016
DOI:
10.1021/acs.analchem.6b03407
Type:
Article
ISSN:
0003-2700; 1520-6882
Sponsors:
The authors are thankful for financial support from KAUST (BAS/1/1346-01-01). Technical guidance and support from the KAUST Core Laboratories is appreciated.
Additional Links:
http://pubs.acs.org/doi/abs/10.1021/acs.analchem.6b03407
Appears in Collections:
Articles; Advanced Nanofabrication, Imaging and Characterization Core Lab

Full metadata record

DC FieldValue Language
dc.contributor.authorSimoes, Filipa R. F.en
dc.contributor.authorBatra, Nitin M.en
dc.contributor.authorWarsama, Bashir H.en
dc.contributor.authorCanlas, Christianen
dc.contributor.authorPatole, Shashikanten
dc.contributor.authorYapici, Tahir F.en
dc.contributor.authorCosta, Pedro M. F. J.en
dc.date.accessioned2017-01-29T13:51:36Z-
dc.date.available2017-01-29T13:51:36Z-
dc.date.issued2016-10-25en
dc.identifier.citationSimoes FRF, Batra NM, Warsama BH, Canlas CG, Patole S, et al. (2016) Elemental Quantification and Residues Characterization of Wet Digested Certified and Commercial Carbon Materials. Analytical Chemistry 88: 11783–11790. Available: http://dx.doi.org/10.1021/acs.analchem.6b03407.en
dc.identifier.issn0003-2700en
dc.identifier.issn1520-6882en
dc.identifier.doi10.1021/acs.analchem.6b03407en
dc.identifier.urihttp://hdl.handle.net/10754/622753-
dc.description.abstractInductively coupled plasma optical emission spectroscopy (ICP-OES) is a common, relatively low cost, and straightforward analytical technique for the study of trace quantities of metals in solid materials, but its applicability to nanocarbons (e.g., graphene and nanotubes) has suffered from the lack of efficient digestion steps and certified reference materials (CRM). Here, various commercial and certified graphitic carbon materials were subjected to aen
dc.description.sponsorshipThe authors are thankful for financial support from KAUST (BAS/1/1346-01-01). Technical guidance and support from the KAUST Core Laboratories is appreciated.en
dc.publisherAmerican Chemical Society (ACS)en
dc.relation.urlhttp://pubs.acs.org/doi/abs/10.1021/acs.analchem.6b03407en
dc.titleElemental Quantification and Residues Characterization of Wet Digested Certified and Commercial Carbon Materialsen
dc.typeArticleen
dc.contributor.departmentImaging and Characterization Core Laben
dc.identifier.journalAnalytical Chemistryen
dc.contributor.institutionPhysical Science and Engineering Divisionen
dc.contributor.institutionAnalytical Core Laboratoryen
kaust.authorCanlas, Christianen
kaust.grant.numberBAS/1/1346-01-01en
All Items in KAUST are protected by copyright, with all rights reserved, unless otherwise indicated.