The Dynamics of a Doubly Clamped Microbeam Near the Primary Resonance: Experimental and Analytical Investigation

Handle URI:
http://hdl.handle.net/10754/621351
Title:
The Dynamics of a Doubly Clamped Microbeam Near the Primary Resonance: Experimental and Analytical Investigation
Authors:
Masri, Karim M.; Jaber, Nizar; Younis, Mohammad I. ( 0000-0002-9491-1838 )
Abstract:
We present experimental and analytical investigation of the dynamics of a doubly clamped microbeam near its primary resonance. The microbeam is excited electrostatically by an electrode on the first half of the beam. These microbeams are fabricated using polyimide as structural layer coated with nickel from top and chromium and gold layers from bottom. A noise signal is applied to experimentally detect the natural frequencies. Then, frequency sweep tests are generated for various values of DC bias revealing hardening, transition, and softening behavior of the microbeam. We report for the first time the transition from lower stable state, to unstable state, and then to large stable state experimentally. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. Shooting method is used to find the periodic motion and is utilized to generate frequency response curves. The curves show good agreement with the experimental results with hardening behavior at lower DC voltage then softening at higher voltage loads and dynamic pull-in. © Copyright 2015 by ASME.
KAUST Department:
Physical Sciences and Engineering (PSE) Division
Citation:
Masri KM, Jaber NR, Younis MI (2015) The Dynamics of a Doubly Clamped Microbeam Near the Primary Resonance: Experimental and Analytical Investigation. Volume 4: 20th Design for Manufacturing and the Life Cycle Conference; 9th International Conference on Micro- and Nanosystems. Available: http://dx.doi.org/10.1115/DETC2015-47141.
Publisher:
ASME International
Journal:
Volume 4: 20th Design for Manufacturing and the Life Cycle Conference; 9th International Conference on Micro- and Nanosystems
Conference/Event name:
ASME 2015 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2015
Issue Date:
20-Jan-2016
DOI:
10.1115/DETC2015-47141
Type:
Conference Paper
Appears in Collections:
Conference Papers; Physical Sciences and Engineering (PSE) Division

Full metadata record

DC FieldValue Language
dc.contributor.authorMasri, Karim M.en
dc.contributor.authorJaber, Nizaren
dc.contributor.authorYounis, Mohammad I.en
dc.date.accessioned2016-11-03T06:58:17Z-
dc.date.available2016-11-03T06:58:17Z-
dc.date.issued2016-01-20en
dc.identifier.citationMasri KM, Jaber NR, Younis MI (2015) The Dynamics of a Doubly Clamped Microbeam Near the Primary Resonance: Experimental and Analytical Investigation. Volume 4: 20th Design for Manufacturing and the Life Cycle Conference; 9th International Conference on Micro- and Nanosystems. Available: http://dx.doi.org/10.1115/DETC2015-47141.en
dc.identifier.doi10.1115/DETC2015-47141en
dc.identifier.urihttp://hdl.handle.net/10754/621351-
dc.description.abstractWe present experimental and analytical investigation of the dynamics of a doubly clamped microbeam near its primary resonance. The microbeam is excited electrostatically by an electrode on the first half of the beam. These microbeams are fabricated using polyimide as structural layer coated with nickel from top and chromium and gold layers from bottom. A noise signal is applied to experimentally detect the natural frequencies. Then, frequency sweep tests are generated for various values of DC bias revealing hardening, transition, and softening behavior of the microbeam. We report for the first time the transition from lower stable state, to unstable state, and then to large stable state experimentally. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. Shooting method is used to find the periodic motion and is utilized to generate frequency response curves. The curves show good agreement with the experimental results with hardening behavior at lower DC voltage then softening at higher voltage loads and dynamic pull-in. © Copyright 2015 by ASME.en
dc.publisherASME Internationalen
dc.titleThe Dynamics of a Doubly Clamped Microbeam Near the Primary Resonance: Experimental and Analytical Investigationen
dc.typeConference Paperen
dc.contributor.departmentPhysical Sciences and Engineering (PSE) Divisionen
dc.identifier.journalVolume 4: 20th Design for Manufacturing and the Life Cycle Conference; 9th International Conference on Micro- and Nanosystemsen
dc.conference.date2 August 2015 through 5 August 2015en
dc.conference.nameASME 2015 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2015en
dc.contributor.institutionDepartment of Mechanical Engineering, State University of New York, Binghamton, NY, United Statesen
kaust.authorJaber, Nizaren
kaust.authorYounis, Mohammad I.en
All Items in KAUST are protected by copyright, with all rights reserved, unless otherwise indicated.