A geometric approach for fault detection and isolation of stator short circuit failure in a single asynchronous machine

Handle URI:
http://hdl.handle.net/10754/577098
Title:
A geometric approach for fault detection and isolation of stator short circuit failure in a single asynchronous machine
Authors:
Khelouat, Samir; Benalia, Atallah; Boukhetala, Djamel; Laleg-Kirati, Taous-Meriem ( 0000-0001-5944-0121 )
Abstract:
This paper deals with the problem of detection and isolation of stator short-circuit failure in a single asynchronous machine using a geometric approach. After recalling the basis of the geometric approach for fault detection and isolation in nonlinear systems, we will study some structural properties which are fault detectability and isolation fault filter existence. We will then design filters for residual generation. We will consider two approaches: a two-filters structure and a single filter structure, both aiming at generating residuals which are sensitive to one fault and insensitive to the other faults. Some numerical tests will be presented to illustrate the efficiency of the method.
KAUST Department:
Applied Mathematics and Computational Science Program
Publisher:
Institute of Electrical and Electronics Engineers (IEEE)
Journal:
2012 American Control Conference (ACC)
Issue Date:
Jun-2012
DOI:
10.1109/acc.2012.6315454
Type:
Conference Paper
ISSN:
07431619
ISBN:
9781457710957
Appears in Collections:
Conference Papers; Applied Mathematics and Computational Science Program

Full metadata record

DC FieldValue Language
dc.contributor.authorKhelouat, Samiren
dc.contributor.authorBenalia, Atallahen
dc.contributor.authorBoukhetala, Djamelen
dc.contributor.authorLaleg-Kirati, Taous-Meriemen
dc.date.accessioned2015-09-10T14:18:00Zen
dc.date.available2015-09-10T14:18:00Zen
dc.date.issued2012-06en
dc.identifier.isbn9781457710957en
dc.identifier.issn07431619en
dc.identifier.doi10.1109/acc.2012.6315454en
dc.identifier.urihttp://hdl.handle.net/10754/577098en
dc.description.abstractThis paper deals with the problem of detection and isolation of stator short-circuit failure in a single asynchronous machine using a geometric approach. After recalling the basis of the geometric approach for fault detection and isolation in nonlinear systems, we will study some structural properties which are fault detectability and isolation fault filter existence. We will then design filters for residual generation. We will consider two approaches: a two-filters structure and a single filter structure, both aiming at generating residuals which are sensitive to one fault and insensitive to the other faults. Some numerical tests will be presented to illustrate the efficiency of the method.en
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en
dc.titleA geometric approach for fault detection and isolation of stator short circuit failure in a single asynchronous machineen
dc.typeConference Paperen
dc.contributor.departmentApplied Mathematics and Computational Science Programen
dc.identifier.journal2012 American Control Conference (ACC)en
dc.contributor.institutionLCP Lab, Ecole Polytechnique of Algiers, Algeriaen
dc.contributor.institutionLaboratoire d'Analyse et Commande des Systmes d'Energie et Rseaux Electriques, LACoSERE Universit d'Amar Telidji, Laghouat, Algeriaen
kaust.authorLaleg-Kirati, Taous-Meriemen
All Items in KAUST are protected by copyright, with all rights reserved, unless otherwise indicated.