This paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.
KAUST Department:
Electrical Engineering Program; Electromechanical Microsystems & Polymer Integration Research Lab (EMPIRe); Computer, Electrical and Mathematical Sciences and Engineering (CEMSE) Division
Publisher:
Institute of Electrical and Electronics Engineers (IEEE)
Journal:
2013 IEEE Wireless Power Transfer (WPT)
Conference/Event name:
2013 IEEE Wireless Power Transfer, WPT 2013
Issue Date:
May-2013
DOI:
10.1109/WPT.2013.6556925
Type:
Conference Paper
ISBN:
9781467350082
Appears in Collections:
Conference Papers; Electrical Engineering Program; Computer, Electrical and Mathematical Sciences and Engineering (CEMSE) Division

Full metadata record

DC FieldValue Language
dc.contributor.authorYi, Yingen
dc.contributor.authorButtner, Ulrichen
dc.contributor.authorFan, Yiqiangen
dc.contributor.authorFoulds, Ian G.en
dc.date.accessioned2015-08-04T07:13:23Zen
dc.date.available2015-08-04T07:13:23Zen
dc.date.issued2013-05en
dc.identifier.isbn9781467350082en
dc.identifier.doi10.1109/WPT.2013.6556925en
dc.identifier.urihttp://hdl.handle.net/10754/564713en
dc.description.abstractThis paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.en
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en
dc.subject3-Coil systemen
dc.subjectPTEen
dc.subjectResonance frequencyen
dc.subjecttransfer distanceen
dc.title3-Coil resonance-based wireless power transfer system for implantable electronicen
dc.typeConference Paperen
dc.contributor.departmentElectrical Engineering Programen
dc.contributor.departmentElectromechanical Microsystems & Polymer Integration Research Lab (EMPIRe)en
dc.contributor.departmentComputer, Electrical and Mathematical Sciences and Engineering (CEMSE) Divisionen
dc.identifier.journal2013 IEEE Wireless Power Transfer (WPT)en
dc.conference.date15 May 2013 through 16 May 2013en
dc.conference.name2013 IEEE Wireless Power Transfer, WPT 2013en
dc.conference.locationPerugiaen
kaust.authorYi, Yingen
kaust.authorButtner, Ulrichen
kaust.authorFan, Yiqiangen
kaust.authorFoulds, Ian G.en
All Items in KAUST are protected by copyright, with all rights reserved, unless otherwise indicated.