In-line coagulation prior to UF of treated domestic wastewater - foulants removal, fouling control and phosphorus removal

Handle URI:
http://hdl.handle.net/10754/562203
Title:
In-line coagulation prior to UF of treated domestic wastewater - foulants removal, fouling control and phosphorus removal
Authors:
Zheng, Xing; Plume, Stephan; Ernst, Mathias; Croue, Jean-Philippe; Jekel, Martin R.
Abstract:
The present work investigated fouling control and phosphorus removal by applying in-line coagulation prior to ultrafiltration (UF) of treated domestic wastewater. Experiments were conducted in both lab- and pilot-scale under close to neutral pH condition. Lab-scale foulant removal tests showed that increasing the dosage of FeCl3, AlCl3 and polymeric aluminum chloride (PACl) can improve biopolymer removal. Specifically, PACl reduced preferentially the proteinaceous fraction of biopolymer while the other two coagulants showed no significant preference. The filterability of water samples was improved after coagulation, which is contributed to biopolymer removal and the formation of larger particles. Pilot UF experiments demonstrated that in-line coagulation improved the performance of UF to a large extent. Within 0.037-0.148mmol Me3+/L dosage range, adding more FeCl3 and AlCl3 slowed down the development of trans-membrane pressure (TMP) correspondingly, while changing PACl dosage showed little effect on the variation of TMP increase rate. Further investigations indicated that PACl related precipitates contributed to more irreversible fouling than that which the monomeric coagulants made. Fouling control is thus considered as a co-effect determined by foulant removal efficiency, fouling layer structure and the adherence of hydrolysis products/precipitates onto the membrane. With respect to phosphorus removal, dosing FeCl3 and AlCl3 achieved higher removal efficiency than using PACl. Based on lab- and pilot-scale results, dosing FeCl3 and AlCl3 at a relative dosage of over 2.5mol Me3+ per mol total phosphorus (TP) in feedwater is necessarily required to keep the TP concentration under 50μg/L in UF permeate. © 2012 Elsevier B.V.
KAUST Department:
Water Desalination and Reuse Research Center (WDRC); Water Desalination & Reuse Research Cntr; Biological and Environmental Sciences and Engineering (BESE) Division
Publisher:
Elsevier
Journal:
Journal of Membrane Science
Issue Date:
Jun-2012
DOI:
10.1016/j.memsci.2012.02.051
Type:
Article
ISSN:
03767388
Sponsors:
This study was financed by the Federal Ministry for Education (BMBF, Germany (Contract no.: 02WA1016)). The financing agencies are gratefully acknowledged. The authors appreciate Miss Katrin Noack and Mr. Christopher Gabler from the Chair of Water Quality Control (TU Berlin, Germany) for their technical support, Mr. M. Kempf and Mr. Foth from Berlin Water Company (BWB) for their assistance at the WWTP Ruhleben; and Ms. Dana Herriman from the Department of Civil and Environmental Engineering (University of Waterloo) for her editing contributions.
Appears in Collections:
Articles; Water Desalination and Reuse Research Center (WDRC); Biological and Environmental Sciences and Engineering (BESE) Division

Full metadata record

DC FieldValue Language
dc.contributor.authorZheng, Xingen
dc.contributor.authorPlume, Stephanen
dc.contributor.authorErnst, Mathiasen
dc.contributor.authorCroue, Jean-Philippeen
dc.contributor.authorJekel, Martin R.en
dc.date.accessioned2015-08-03T09:47:11Zen
dc.date.available2015-08-03T09:47:11Zen
dc.date.issued2012-06en
dc.identifier.issn03767388en
dc.identifier.doi10.1016/j.memsci.2012.02.051en
dc.identifier.urihttp://hdl.handle.net/10754/562203en
dc.description.abstractThe present work investigated fouling control and phosphorus removal by applying in-line coagulation prior to ultrafiltration (UF) of treated domestic wastewater. Experiments were conducted in both lab- and pilot-scale under close to neutral pH condition. Lab-scale foulant removal tests showed that increasing the dosage of FeCl3, AlCl3 and polymeric aluminum chloride (PACl) can improve biopolymer removal. Specifically, PACl reduced preferentially the proteinaceous fraction of biopolymer while the other two coagulants showed no significant preference. The filterability of water samples was improved after coagulation, which is contributed to biopolymer removal and the formation of larger particles. Pilot UF experiments demonstrated that in-line coagulation improved the performance of UF to a large extent. Within 0.037-0.148mmol Me3+/L dosage range, adding more FeCl3 and AlCl3 slowed down the development of trans-membrane pressure (TMP) correspondingly, while changing PACl dosage showed little effect on the variation of TMP increase rate. Further investigations indicated that PACl related precipitates contributed to more irreversible fouling than that which the monomeric coagulants made. Fouling control is thus considered as a co-effect determined by foulant removal efficiency, fouling layer structure and the adherence of hydrolysis products/precipitates onto the membrane. With respect to phosphorus removal, dosing FeCl3 and AlCl3 achieved higher removal efficiency than using PACl. Based on lab- and pilot-scale results, dosing FeCl3 and AlCl3 at a relative dosage of over 2.5mol Me3+ per mol total phosphorus (TP) in feedwater is necessarily required to keep the TP concentration under 50μg/L in UF permeate. © 2012 Elsevier B.V.en
dc.description.sponsorshipThis study was financed by the Federal Ministry for Education (BMBF, Germany (Contract no.: 02WA1016)). The financing agencies are gratefully acknowledged. The authors appreciate Miss Katrin Noack and Mr. Christopher Gabler from the Chair of Water Quality Control (TU Berlin, Germany) for their technical support, Mr. M. Kempf and Mr. Foth from Berlin Water Company (BWB) for their assistance at the WWTP Ruhleben; and Ms. Dana Herriman from the Department of Civil and Environmental Engineering (University of Waterloo) for her editing contributions.en
dc.publisherElsevieren
dc.subjectBiopolymer foulingen
dc.subjectIn-line coagulationen
dc.subjectPhosphorus removalen
dc.subjectSecondary effluenten
dc.subjectUltrafiltrationen
dc.titleIn-line coagulation prior to UF of treated domestic wastewater - foulants removal, fouling control and phosphorus removalen
dc.typeArticleen
dc.contributor.departmentWater Desalination and Reuse Research Center (WDRC)en
dc.contributor.departmentWater Desalination & Reuse Research Cntren
dc.contributor.departmentBiological and Environmental Sciences and Engineering (BESE) Divisionen
dc.identifier.journalJournal of Membrane Scienceen