Disposable screen printed graphite electrode for the direct electrochemical determination of ibuprofen in surface water

Handle URI:
http://hdl.handle.net/10754/338597
Title:
Disposable screen printed graphite electrode for the direct electrochemical determination of ibuprofen in surface water
Authors:
Amin, Sidra; Soomro, M. Tahir ( 0000-0001-9898-7015 ) ; Memon, Najma; Solangi, Amber R.; Sirajuddin; Qureshi, Tahira; Behzad, Ali Reza
Abstract:
The potential of square wave voltammetry (SWV) for the determination of ibuprofen in aqueous solution, applying baseline correction, is reported. A screen printed graphite electrodes (SPGEs), especially pretreated for this purpose, were used to investigate the electrochemical oxidation and detection of ibuprofen. After optimization of SWV parameters, measurements were carried out at 200 Hz modulation frequency, 4 mV step potential and 40 mV pulse amplitude for the determination of ibuprofen. The surfaces of both untreated and pretreated SPGEs were characterized by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The electro-catalytic properties of both the electrodes were correlated with the surface treatment. The pretreated screen printed graphite electrode exhibited a high sensitivity toward ibuprofen even in low concentration. The developed method was found rapid, cost-effective and reproducible for in-field ibuprofen detection.
KAUST Department:
Advanced Nanofabrication, Imaging and Characterization Core Lab
Citation:
Disposable screen printed graphite electrode for the direct electrochemical determination of ibuprofen in surface water 2014, 1-2:8 Environmental Nanotechnology, Monitoring & Management
Publisher:
Elsevier BV
Journal:
Environmental Nanotechnology, Monitoring & Management
Issue Date:
1-Aug-2014
DOI:
10.1016/j.enmm.2014.07.001
Type:
Article
ISSN:
22151532
Additional Links:
http://linkinghub.elsevier.com/retrieve/pii/S2215153214000063
Appears in Collections:
Articles; Advanced Nanofabrication, Imaging and Characterization Core Lab

Full metadata record

DC FieldValue Language
dc.contributor.authorAmin, Sidraen
dc.contributor.authorSoomro, M. Tahiren
dc.contributor.authorMemon, Najmaen
dc.contributor.authorSolangi, Amber R.en
dc.contributor.authorSirajuddinen
dc.contributor.authorQureshi, Tahiraen
dc.contributor.authorBehzad, Ali Rezaen
dc.date.accessioned2015-01-20T14:09:22Z-
dc.date.available2015-01-20T14:09:22Z-
dc.date.issued2014-08-01en
dc.identifier.citationDisposable screen printed graphite electrode for the direct electrochemical determination of ibuprofen in surface water 2014, 1-2:8 Environmental Nanotechnology, Monitoring & Managementen
dc.identifier.issn22151532en
dc.identifier.doi10.1016/j.enmm.2014.07.001en
dc.identifier.urihttp://hdl.handle.net/10754/338597en
dc.description.abstractThe potential of square wave voltammetry (SWV) for the determination of ibuprofen in aqueous solution, applying baseline correction, is reported. A screen printed graphite electrodes (SPGEs), especially pretreated for this purpose, were used to investigate the electrochemical oxidation and detection of ibuprofen. After optimization of SWV parameters, measurements were carried out at 200 Hz modulation frequency, 4 mV step potential and 40 mV pulse amplitude for the determination of ibuprofen. The surfaces of both untreated and pretreated SPGEs were characterized by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The electro-catalytic properties of both the electrodes were correlated with the surface treatment. The pretreated screen printed graphite electrode exhibited a high sensitivity toward ibuprofen even in low concentration. The developed method was found rapid, cost-effective and reproducible for in-field ibuprofen detection.en
dc.language.isoenen
dc.publisherElsevier BVen
dc.relation.urlhttp://linkinghub.elsevier.com/retrieve/pii/S2215153214000063en
dc.rightsArchived with thanks to Environmental Nanotechnology, Monitoring & Managementen
dc.subjectIbuprofenen
dc.subjectWastewateren
dc.subjectSquare wave voltammetryen
dc.subjectBaseline correctionen
dc.titleDisposable screen printed graphite electrode for the direct electrochemical determination of ibuprofen in surface wateren
dc.typeArticleen
dc.contributor.departmentAdvanced Nanofabrication, Imaging and Characterization Core Laben
dc.identifier.journalEnvironmental Nanotechnology, Monitoring & Managementen
dc.eprint.versionPublisher's Version/PDFen
dc.contributor.institutionCenter of Excellence in Environmental Studies, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabiaen
dc.contributor.institutionNational Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistanen
dc.contributor.affiliationKing Abdullah University of Science and Technology (KAUST)en
kaust.authorBehzad, Ali Rezaen
This item is licensed under a Creative Commons License
Creative Commons
All Items in KAUST are protected by copyright, with all rights reserved, unless otherwise indicated.